State-of-the-art facilities available for users.
| # | Name of the Instrument | Make / Model | Specifications |
|---|---|---|---|
| 1 | Autosorb iQ- Chemisorption (& Physisorption) Gas Sorption Analyzer | Quantachrome / AutosorbiQ | Physisorption and Chemisorption studies |
| 2 | Gas Chromatography (GC) Instrument | Agilent GC 7820A | Detectors: Flame Ionization Detector (FID) |
| 3 | Thermo Gravimetric Analyzer Instrument | Netzsch-STA 2500 Regulus | Maximum sample temperature: 1600°C Furnace: RT to 1600°C (0.001 to 50 K/min) Temp precision: 0.3 K Thermocouple: Type S Atmosphere: Vacuum-tight 10-4 m bar |
| 4 | DSC Instrument | DSC 214 Polyma, NETZSCH | Temperature: 0–600°C Heating: 0.02–300 K/min Cooling: 200 K/min TAWN resolution: 0.12/0.2 Sensitivity: 11.9 Indium response ratio: >90 mW/°C |
| 5 | Panalytical XRD | Powder X-ray Diffractometer – PANalytical, Xpert3 | Sample: Powder / Thin films / SAXS Scan range: 5–100° |
| 6 | FT-IR Instrument | Shimadzu IR Tracer-100 | IR Region: 400–12500 cm⁻¹ Modes: KBr, ATR, SRM, DRS |
| 7 | High Resolution Mass Spectrometry | 6230B TOF, Agilent | Sample: Solid / Liquid / Gel Mass: 50–3200 amu Resolution: 40000 FWHM Accuracy: <1 ppm |
| 8 | Microwave Reactor | Anton Paar – Multiwave Pro | Vessel: Teflon 80 mL Pressure: 10–12 bar Power: 1800 W Temp: RT–300°C Sensor: IR |
| 9 | Biosensor Tester | CHI760E | Scan rate: 0.000001–5000 V/s Potential: -10 to 10 V Accuracy: ±1 mV Current: ±250 mA |
| 10 | Freeze Dryer | FreeZone 4.5 | Condenser: -105°C Capacity: 4.5 L Chamber: 12 ports Vessels: 200–1000 mL |
| 11 | Stereo-zoom Microscope, Polarized Microscope | Microscope Camera, MC170 HD, Leica | 5 MP HD digital microscope camera with C-mount interface 30 fps with 5 MP resolution |
| 12 | UV Photoreactor Instrument | LUZCHEM – LZC-4V | Number of slots booking – Maximum 1 per day |
| 13 | Inert Atmosphere Glove Box | DANVEC – 8 Port, IT Technologies Pte Ltd, Singapore | Inert atmosphere reactions |
| 14 | Fuel Cell Analyser and RRDE Instruments | CH Instruments CHI608E-3A | Electrochemical workstation with Potentiostat / Galvanostat Rotating Ring Disk Electrode apparatus with purge & stir facility |
| 15 | Rotary Evaporator | IKA RV-10 Rotavapor | Rotary evaporator with KNF vacuum pump and indigenous chiller |
| 16 | Gel Permeation Chromatography (GPC) | Agilent Technologies | Separation of molecular weight range: 5 kDa to 400 kDa |
| 17 | Dissolution and Diffusion Cell Apparatus | Agilent Technologies | Agilent dissolution apparatus (708-DS) Rotor speed: 10–250 RPM (±1) Water bath: RT–55°C (±1) International pharmacopeia specifications Hydraulic press for pellet |
| 18 | Spectrofluorimeter with Lifetime (TCSPC) | FLS-1000 Spectrofluorimeter, Edinburgh | Steady state emission/excitation (200–850 nm) Lifetime: nano, pico & micro second scale Anisotropy for solution, powder & thin films Diode lasers/LEDs: 380, 450, 570, 635 nm |
| 19 | Contact Angle Measuring System | Kyowa Interface Science Co., Ltd. | Range: 0–180° ±0.1° Method: Sessile drop Samples: Powders, films, pellets Droplet deposition: Up/down motion |
| 20 | Microwave Organic Synthesizer | Biotage Initiator+ Microwave System (EU) | Biotage® Microwave reaction kit Magnetic stir bars 0.5–2 mL |
| 21 | Electrospinning Unit | ESPIN NANO – Model V1-VH | Horizontal & vertical arrangement 0–40 kV 2–50 mL |
| 22 | Electrochemical Workstation | Origalys – OGF 500 | 4 channels Applied voltage: ±15 V Maximum current: ±500 mA |
| 23 | Probe Sonicator | S Clean Model SM-500 PS | Ultrasonic power: 500 W Frequency: 20 kHz Probe: 19 mm Sample volume: 25–500 mL |
| 24 | Spin Coating System | Model No: EZspin-A1 | 0–2 mL spinning solution |
| 25 | UV-Visible Spectrometer | Agilent | Absorption: 200–1100 nm (solution & thin films) Temperature dependent: 0–100°C Fibre optic source for powder & remote samples RGB colour measurements |
| 26 | Electrochemical Workstation | Origalys | 1 channel Applied voltage: ±15 V Maximum current: ±500 mA |
| 27 | UV-Visible Spectrophotometer | Shimadzu | Double beam Only liquid samples Cuvette available (3 mL) |
| 28 | Tubular Furnace | LABTHERM | Up to 1150°C under nitrogen atmosphere |
| 29 | Automatic Battery Cycler | WonATech WBCS3000 | Application: Supercapacitors & batteries Techniques: CV & Galvanostatic cycling Channels: 4 Voltage: ±2.0 V Current: 1 A |